{"id":373,"date":"2021-02-01T13:57:01","date_gmt":"2021-02-01T12:57:01","guid":{"rendered":"http:\/\/kcb.ue.wroc.pl\/?page_id=373"},"modified":"2021-02-14T23:31:22","modified_gmt":"2021-02-14T22:31:22","slug":"aparatura","status":"publish","type":"page","link":"https:\/\/kcb.ue.wroc.pl\/index.php\/aparatura\/","title":{"rendered":"Aparatura"},"content":{"rendered":"\n<h4><span style=\"color: #000080;\"><strong>W Katedrze Chemii Bioorganicznej dost\u0119pna jest nast\u0119puj\u0105ca aparatura:<\/strong><\/span><\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-1024x768.jpg\" alt=\"\" class=\"wp-image-383\" width=\"176\" height=\"132\" srcset=\"https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-1024x768.jpg 1024w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-300x225.jpg 300w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-150x113.jpg 150w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-768x576.jpg 768w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-1536x1152.jpg 1536w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/IMG_20190215_105157-1-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 176px) 100vw, 176px\" \/><figcaption><strong>Spektrometr FTIR Nicolet 6700, Thermo Scientific<\/strong><\/figcaption><\/figure><\/div>\n\n\n\n<p><span style=\"color: #000080;\"><strong>1.Spektrometr FTIR Nicolet 6700, Thermo Scientific :<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Spektrometr fourierowski na zakres 50-12000 cm-1 (w dalekiej, \u015bredniej i bliskiej podczerwieni).<\/span><br \/><span style=\"color: #000000;\">Wyposa\u017cony m.in. w przystawk\u0119 do pomiar\u00f3w odbiciowych i technik\u0105 ATR, zestaw do robienia pastylek z KBr i zestaw komputerowy z programem analizy widm OMNIC.<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu<\/span>:<span style=\"color: #0000ff;\"><strong> dr Wojciech S\u0105siadek <br \/><\/strong><\/span><\/p>\n<p><span style=\"color: #000080;\"><strong>2. Spektrofotometr UV-2600i<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Dwuwi\u0105zkowy spektrofotometr UV o zakresie pomiarowym od 190 do 900 nm (lampa deuterowa i wolframowa halogenowa) do pomiar\u00f3w absorbancji lub transmitancji<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu:<\/span><span style=\"color: #0000ff;\"><strong> dr Wojciech S\u0105siadek <br \/><\/strong><\/span><\/p>\n<p><span style=\"color: #000080;\"><strong>3. Spektrofluorymetr PTI NIR-VIS<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Spektrofluorymetr przeznaczony do pomiar\u00f3w fluore- i fosforescencji w zakresie NIR-VIS w konfiguracji &#8222;T&#8221;, wyposa\u017cony w detektory: InGaAs (do 1200 nm) oraz fotopowielacz (od 200 do 1000 nm)<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu:<\/span><span style=\"color: #0000ff;\"><strong> dr Wojciech S\u0105siadek <br \/><\/strong><\/span><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_225241-1.jpg\" alt=\"\" class=\"wp-image-394\" width=\"164\" height=\"184\" srcset=\"https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_225241-1.jpg 748w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_225241-1-268x300.jpg 268w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_225241-1-134x150.jpg 134w\" sizes=\"auto, (max-width: 164px) 100vw, 164px\" \/><figcaption><strong>Prasa \u015blimakowa PS-200<\/strong><\/figcaption><\/figure><\/div>\n\n\n\n<p style=\"text-align: left;\"><strong><span style=\"color: #000080;\">4. Prasa \u015blimakowa PS-200<\/span><\/strong><\/p>\n<p style=\"text-align: left;\"><span style=\"color: #000000;\">Przeznaczona do t\u0142oczenia metod\u0105 na \u201ezimno\u201d, oleju z nasion ro\u015blin oleistych. Mo\u017cliwo\u015b\u0107 kontroli parametr\u00f3w t\u0142oczenia tj. pr\u0119dko\u015b\u0107 obrotu wa\u0142u i temperatury<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu:<strong><span style=\"color: #0000ff;\"> dr Adam Zaj\u0105c<\/span><\/strong><\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong><span style=\"color: #000080;\">5. Liofilizator Alpha z Cylindrem Akrylowym<\/span><\/strong><\/p>\n<p><span style=\"color: #000000;\">Liofilizacja materia\u0142\u00f3w biologicznych i \u017cywno\u015bci.<\/span><br><span style=\"color: #000000;\">Wydajno\u015b\u0107 kondensatora lodu 2,5 kg\/24h<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu:<\/span><span style=\"color: #0000ff;\"><strong> dr Adam Zaj\u0105c<\/strong><\/span><\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6-898x1024.jpg\" alt=\"\" class=\"wp-image-409\" width=\"185\" height=\"210\" srcset=\"https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6-898x1024.jpg 898w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6-263x300.jpg 263w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6-131x150.jpg 131w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6-768x876.jpg 768w, https:\/\/kcb.ue.wroc.pl\/wp-content\/uploads\/Screenshot_20210205_230056-6.jpg 1080w\" sizes=\"auto, (max-width: 185px) 100vw, 185px\" \/><figcaption><strong>Wir\u00f3wka Mpw-56<\/strong><\/figcaption><\/figure><\/div>\n\n\n\n<p>\u00a0<\/p>\n<p><span style=\"color: #000080;\"><strong>6. Wir\u00f3wka Mpw-56<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Ma\u0142a wir\u00f3wka laboratoryjna przeznaczona do u\u017cytku og\u00f3lnego <\/span><span style=\"color: #000000;\">(z akcesoriami). Obroty 100-6000 obr\/min.<\/span><\/p>\n<p><span style=\"color: #000000;\">W razie pyta\u0144 dotycz\u0105cych naukowego wykorzystania aparatury zapraszamy do kontaktu:<span style=\"color: #0000ff;\"><strong> dr Adam Zaj\u0105c<\/strong><\/span><\/span><\/p>\n<p>\u00a0<\/p>\n<p><span style=\"color: #000080;\"><strong>7. Komora Klimatyczna Hpp 110<\/strong><\/span><\/p>\n<p><span style=\"color: #000000;\">Urz\u0105dzenia znajduj\u0105 najcz\u0119\u015bciej zastosowanie przy przeprowadzaniu test\u00f3w stabilno\u015bci zgodnie z ICH, GMP lub IFSCC w przemy\u015ble farmaceutycznym, kosmetycznym i spo\u017cywczym, magazynowaniu klimatyzowanym oraz kondycjonowaniu. Komory klimatyczne nadaj\u0105 si\u0119 tak\u017ce do hodowania kryszta\u0142\u00f3w, ro\u015blin, owad\u00f3w i kr\u0119gowc\u00f3w. Komora wyposa\u017cona jest w o\u015bwietlenie LED gwarantuje naturalne warunki wzrostu. Zakresy ustawianych temperatur: do +70\u00b0C. Zakresy ustawiania wilgotno\u015bci: 10 do 90% RH.<\/span><\/p>\n<p>\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-373","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/pages\/373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/comments?post=373"}],"version-history":[{"count":17,"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/pages\/373\/revisions"}],"predecessor-version":[{"id":437,"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/pages\/373\/revisions\/437"}],"wp:attachment":[{"href":"https:\/\/kcb.ue.wroc.pl\/index.php\/wp-json\/wp\/v2\/media?parent=373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}